Σύμβολο ECOM

Topvex TX/C04 HWH-R-CAV-S

Αριθμός αντικειμένου: 156537

• Topvex is delivered with the Access control system

• Space saving top connection

• High efficient counter-flow heat exchanger

- > 80% dry efficiency (EN 308) at nominal airflow

- No mixing of extract and supply air

- Automatic summer operating

- Cool recovering

• Section defrosting

-

The Topvex counter flow unit TX/C (-S

*

) are pre-configured units with Section defrosting

• Low energy use

- Energy efficient plug fans with EC motors

• Large inspection doors for easy maintenance

-

All main components are easy removable

- Separate electrical cabinet facilitates commissioning and service

• Manufactured in Aluzinc plated sheet metal (AZ185)

- Corrosive class C4 (Industrial and coastal areas with moderate salinity)

- AZ185 sheet metal has more than 50 years of technical lifetime

• Factory tested

Topvex TX/C is designed for meeting the coming energy demands with high heat recovery efficiency and low energy use. To guarantee the high heat recovery efficiency the exchanger is designed for low air speed and by that also a low pressure drop. The supply and extract air filter are designed to have a low pressure drop, without compromising with the filtration efficiency. A low internal pressure drop is essential to keep the energy use down Topvex TX/C features Plug fans with EC technology to ensure high efficiency. The EC-motors has when speed-controlled, 15-20% lower energy consumption compared to a standard frequency controlled asynchrony motor.

100% By-pass of heat exchanger secures lowest possible internal pressure drop during the warm season.

A damper isolates the exchanger during the warm period ensures that there is no undesirable heat recovering.

Constant air volume control is standard and Variable air volume control is available as an accessory.

The Topvex counter flow unit TX/C with item name ending -S are pre-configured units with Section defrosting.

The Section defrosting consist of a pre-wired sectioned damper that divides the heat exchanger in three areas plus the by-pass section. All sections are controlled by individual motors for each section and are connected to a separate, pre-programmed control unit.

Section defrosting will prevent severe ice built up in the heat exchanger and allow defrosting of the heat exchanger, while still providing heat recovery through the defrosting sequence.

When activated by pressure detecting, the damper sections will be cyclic operated. Each section will operate in sequence and compensate low temperature in the exhaust air, by modulating the by-pass and section damper.

Topvex is delivered with the new Access control system. The system includes NaviPad control panel, featuring an easy-to-use intuitive HTML5 user interface.

The protection class of the NaviPad control panel is IP54 and 0-50 C° permitted temperature. The enclosure is not UV resistant and the NaviPad is not for outdoor mounting. Communication between the panel and the controller in the cabinet is possible with up to 100 meters of cable.

The NaviPad is connected via 3 meters flat cable. It is mounted on the Topvex unit or on the wall, easy to detach for handheld use.

Relevant operating data and settings are available in real time and can be changed with a few clicks.

Access control has built-in energy saving features like free cooling, cooling recovery, season related temperatures and airflow control.

Possibility to edit names for the unit, the alarms and control components gives the user options to adapt to different installations needs.

With the system overview dashboard it is possible to monitor several air handling units within a local network.

Standard communication possibilities are: Modbus RTU via RS-485 & TCP/IP & BACnet via IP.

Ordering code.

- Model: TX/C03, TX/C04 and TX/C06.

- Heating coil:

EL

(Electric).

HWL

(Hot water coil-low power).

HWH

(Hot water coil-high power).

None

(No heater).

- Right or Left model: R

(Right),

L

(Left). The side where the supply air is located when viewed from the access side.

- Airflow control: CAV

(Constant air volume).

-

Airflow control (accessory):

VAV

(Variable air volume = constant duct pressure control).

-Section defrosting:

-S

(Section defrosting).

*

Section defrosting is available for all Topvex TX/C. Units with item name ending -S are Section defrosting configured.

I.e. Topvex TX/C03 EL-L-CAV-S.

Τεχνικές παράμετροι

Διαστάσεις και βάρη
Βάρος 299 kg

Supply

Images Performance - Topvex TX/C04 HWH-R-CAV-S - Systemair

Extract

Images Performance - Topvex TX/C04 HWH-R-CAV-S - Systemair
1 Outdoor air

2

Supply air

3

Extract air

4

Exhaust air

Images Dimensions - Topvex TX/C04 HWH-R-CAV-S - Systemair
A B C D E F G H I J K L M

Topvex TX/C04

1860

1279

880

1708

725

104

136

180

190

500

195

300

920

CO2RT-R-D Transmitter - Systemair Αριθμός αντικειμένου: 6993 CO2RT-R-D Transmitter .
Presence detector/IR24-PC - Systemair Αριθμός αντικειμένου: 7288 Presence detector/IR24-PC .
Systemair-1 CO2 duct sensor - Systemair Αριθμός αντικειμένου: 14906 Systemair-1 CO2 duct sensor

CO2 duct sensor, 100 mm

.
Systemair-1M CO2 duct sensor - Systemair Αριθμός αντικειμένου: 14908 Systemair-1M CO2 duct sensor

CO2 duct sensor, 1m cable

.
Systemair-2 CO2 duct sensor - Systemair Αριθμός αντικειμένου: 14907 Systemair-2 CO2 duct sensor

CO2 duct sensor, 200 mm

.
Systemair-E CO2 sensor - Systemair Αριθμός αντικειμένου: 14904 Systemair-E CO2 sensor

CO2 wall unit, no display

.
Systemair-E-D CO2 sensor - Systemair Αριθμός αντικειμένου: 14905 Systemair-E-D CO2 sensor

CO2 wall unit, with display

.
T 120 Timer - Systemair Αριθμός αντικειμένου: 5165 T 120 Timer .
TG-AH1/PT1000 Contact Sensor - Systemair Αριθμός αντικειμένου: 7899 TG-AH1/PT1000 Contact Sensor .
TG-R5/PT1000 Room sensor 0-50° - Systemair Αριθμός αντικειμένου: 5404 TG-R5/PT1000 Room sensor 0-50° .
TG-UH/PT1000 Wall sensor - Systemair Αριθμός αντικειμένου: 35203 TG-UH/PT1000 Wall sensor

temperature range: -30° - +70°C

.
VAV Air Volume Control - Systemair Αριθμός αντικειμένου: 145946 VAV Air Volume Control .
DS 50-30 Flexible connection - Systemair Αριθμός αντικειμένου: 1544 DS 50-30 Flexible connection .
DXRE 50-30-3-2,5 Duct cooler - Systemair Αριθμός αντικειμένου: 7953 DXRE 50-30-3-2,5 Duct cooler

rectangular 500x300mm

.
LDR 50-30 Silencer - Systemair Αριθμός αντικειμένου: 5071 LDR 50-30 Silencer

Rectangular

.
PGK 50-30-3-2,0 Duct cooler - Systemair Αριθμός αντικειμένου: 6608 PGK 50-30-3-2,0 Duct cooler

rectangular 500x300mm

.
VBR 50-30-2 Water heating batt - Systemair Αριθμός αντικειμένου: 5465 VBR 50-30-2 Water heating batt .
BFT TX/C04 Filter Coarse 50% - Systemair Αριθμός αντικειμένου: 209929 BFT TX/C04 Filter Coarse 50%

780x417x430/230/8 G3

.
BFT TX/C04 Filter ePM1 60% - Systemair Αριθμός αντικειμένου: 209927 BFT TX/C04 Filter ePM1 60%

780x417x430/230/12 F7

.
BFT TX/C04 Filter ePM10 60% - Systemair Αριθμός αντικειμένου: 209928 BFT TX/C04 Filter ePM10 60%

780x417x430/230/8 M5

.
Control panel S-E3-DSP - Systemair Αριθμός αντικειμένου: 208997 Control panel S-E3-DSP

Control panel S-E3-DSP with 10m cable

.
Corrigo exp. module CEM15 - Systemair Αριθμός αντικειμένου: 209554 Corrigo exp. module CEM15

Expansion module

.
CVVX 315 Combi grille white - Systemair Αριθμός αντικειμένου: 146261 CVVX 315 Combi grille white .
CVVX 315 Combi grille, black - Systemair Αριθμός αντικειμένου: 8499 CVVX 315 Combi grille, black

for Topvex 1500 (Black)

.
F-T120 Timer frame - Systemair Αριθμός αντικειμένου: 5137 F-T120 Timer frame .
HMH Tube Humidistat IP 54 - Systemair Αριθμός αντικειμένου: 13209 HMH Tube Humidistat IP 54 .
LDR-B 50-30 Silencer, baffle - Systemair Αριθμός αντικειμένου: 9239 LDR-B 50-30 Silencer, baffle .
Preheat.kit Topvex RB50-30 EL - Systemair Αριθμός αντικειμένου: 131086 Preheat.kit Topvex RB50-30 EL .
Push button, impulse - Systemair Αριθμός αντικειμένου: 9693 Push button, impulse .
RVAZ4 24A Actuator 0-10V - Systemair Αριθμός αντικειμένου: 9862 RVAZ4 24A Actuator 0-10V .
Safety switch OTP16T3M 3-pole - Systemair Αριθμός αντικειμένου: 213042 Safety switch OTP16T3M 3-pole

IP65

.
Safety switch OTP16T4M 4-pole - Systemair Αριθμός αντικειμένου: 213044 Safety switch OTP16T4M 4-pole

IP65

.
TG-KH/PT1000 Duct sensor - Systemair Αριθμός αντικειμένου: 202705 TG-KH/PT1000 Duct sensor

temperature range: -30° - +70°C

.
UG3-A4O Smoke detector - Systemair Αριθμός αντικειμένου: 15043 UG3-A4O Smoke detector

Smoke detector

.
VOC Duct sensor - Systemair Αριθμός αντικειμένου: 156813 VOC Duct sensor

24V AC/DC 0-10V, 4-20mA w/ sw. contact

.
VOC Room sensor - Systemair Αριθμός αντικειμένου: 156812 VOC Room sensor

24V AC/DC 0-10V, 4-20mA w/ sw. contact

.
Water-lock - Systemair Αριθμός αντικειμένου: 206263 Water-lock

Ø32 mm

.
ZTR 15-1,0 valve 3-way - Systemair Αριθμός αντικειμένου: 9672 ZTR 15-1,0 valve 3-way

DN 15 Kvs 1,0

.
ZTV 15-0,6 2-way valve - Systemair Αριθμός αντικειμένου: 6571 ZTV 15-0,6 2-way valve

DN 15 Kvs 0,6

.