TLP 315/6,0 Air handl.units

Item Number: 75007

Low noise level

Adjustable voltage control

Supply-air unit with heater

Easily removable inspection cover

G4 filter

A compact unit consisting of a fan, heater and filter in a galvanised sheet steel casing insulated inside with 50 mm of mineral wool. Rubber-sealed sleeve couplings. Neoprene sealing strips and toggle locks. Note that the fan must always be connected to 230 V. Fan run-on is not normally required. (Lowest air velocity 1.5 m/s). Max. output air temperature: 40 °C. The fan may be adjusted by either a transformer or a thyristor.

The heating element is most effectively controlled by a power regulator, pulser and duct sensor.

The filter should be checked regularly and replaced at least twice a year.

Ecodesign

Product
Trade name Systemair
Product name TLP 315/6,0 Tilluftspaket
Basic unit
ErP compliance 2016
SEC Average -9.4 kWh/(m².a)
SEC Cold -25.8 kWh/(m².a)
SEC Warm 0 kWh/(m².a)
SEC Class F
Unit category RVU
Unit type UVU
Drive External MSD or VSD
Heat recovery type None
Temperature ratio (UVU) Not applicable
qv max 806 m³/h
P max 219 W
Sound power level LWA 45 dB(A)
qv ref 0.206 m³/s
Ps ref 50 Pa
SPI 0.248 W/(m³/h)
CTRL 1
MISC 1.1
x-value 1.5
External Leakage 2 %
AEC average 311 kWh
AHS Cold 311 kWh
AEC warm 311 kWh
AHS Average 1,715 kWh/a
AHS Cold 3,355 kWh/a
AHS Warm 776 kWh/a
Units with local demand control
ErP compliance 2018
SEC Average -24.2 kWh/(m².a)
SEC Cold -51.3 kWh/(m².a)
SEC Warm -8.7 kWh/(m².a)
SEC Class C
Unit category RVU
Unit type UVU
Drive External MSD or VSD
Heat recovery type None
Temperature ratio (UVU) Not applicable
qv max 806 m³/h
P max 219 W
Sound power level LWA 45 dB(A)
qv ref 0.2061 m³/s
Ps ref 50 Pa
SPI 0.248 W/(m³/h)
CTRL 1
MISC 1.1
x-value 1.5
External Leakage 2 %
AEC average 163 kWh
AEC cold 163 kWh
AEC warm 163 kWh
AHS Average 2,830 kWh/a
AHS Cold 5,536 kWh/a
AHS Warm 1,280 kWh/a

Technical parameters

Norminal data
Voltage (nominal) 400 V
Frequency 50 Hz
Phase(s) 3~
Phase(s), supply fan 1~
Input power (P1), supply fan 222 W
Current, supply fan 0.974 A
Impeller speed 2,792 r.p.m.
Air flow 48 to 239 L/s
Sound data
Sound pressure level at 3m (20m² Sabin) 48 dB(A)
Protection/Classification
Enclosure class IP44
Insulation class F
Data according to ErP
Energy class, Basic unit F
Energy class, Local demand C
ErP ready ErP 2016
Filter
Filter class, supply air G4
Controller and Sensors
Input power, heater 6 kW
Dimensions and weights
Weight 43 kg
Others
AHU Supply
Heating type Electric
Images Dimensions - TLP 315/6,0 Air handl.units - Systemair
A B C D E F øG H

531

231

529

525

798

745

315

740

Pulser M Temperature control - Systemair Item Number: 5144 Pulser M Temperature control

with Systemair logo / 230/400V

.
RE 1,5 Speed control - Systemair Item Number: 5000 RE 1,5 Speed control

1.5A 1~ 5 step

.
REE 2 Speed control - Systemair Item Number: 5316 REE 2 Speed control

Wall mounted

.
REU 1.5 Speed control - Systemair Item Number: 5004 REU 1.5 Speed control

1.5A 1~ 5 step

.
SG 315 Protection guard - Systemair Item Number: 5611 SG 315 Protection guard .
DTV200 - Systemair Item Number: 6261 DTV200 .
TG-K330 Duct Sensor 0-30°C - Systemair Item Number: 5160 TG-K330 Duct Sensor 0-30°C .
TG-R530 Room sensor 0-30°C - Systemair Item Number: 5163 TG-R530 Room sensor 0-30°C

with Systemair logo

.
FK 315 Fast clamp - Systemair Item Number: 1613 FK 315 Fast clamp

SYSTEMAIR FK Fast clamps each 315 dia

.
LDC 315-900 Silencer - Systemair Item Number: 5197 LDC 315-900 Silencer .
RSK-315 Back draft damper - Systemair Item Number: 5604 RSK-315 Back draft damper

Systemair RSK damper 315,steel,8 pcs/box 160 pcs/pallet

.
Filter TLP 200-315 Coarse 60% - Systemair Item Number: 203263 Filter TLP 200-315 Coarse 60%

200-315/6 430x425 with frame G4

.