ECOM Symbol ECOM Symbol ECOM Symbol

SAVE VTR 100/B

Item Number: 98080

Main features:

• High energy-efficiency rotary heat exchanger with EC - technology fans

• Moisture transfer function to minimize condensation in supply air during wintertime

• Demand control regulation with the built-in humidity sensor

• SAVE Touch control with a touch display and Startup Wizard for easy commissioning

• Connection board for easy access and connection of accessories

• Modbus communication RS-485 as standard

• Internet access module is available as accessory

• Moisture transfer function to minimize condensation in supply air during wintertime

 

SAVE VTR 100/B is adapted for ventilation of smaller houses and apartments with an area of 100 m².

 

SAVE VTR 100/B is designed for both vertical and horizontal mounting. It can be installed in a kitchen cupboard or between them and then covered with a custom furniture panel.

Electrical heater is available as an accessory.

A duct from the cooker hood can be connected to a separate bypass duct on the unit, so the air from the cooker hood is led straight to the exhaust fan and not through the heat exchanger in the unit.

Systemair offers several cooker hoods for a direct insertion into SAVE VTR 100/B and easy wiring to the connection box. The unit has a Cooker Hood function which can be activated via cooker hood.

 

SAVE VTR 100/B has skinned panels and comes with a complete control functionality. The unit is equipped with a high efficiency variable speed rotating heat exchanger and a moisture transfer function that regulates the rotation speed of the rotor. Energy efficient fans with EC motors as well as low-pressure filters reduce the energy consumptions and gives low SFP factor (Specific Fan Power) while maintaining low sound levels. A built-in humidity sensor in the extract air can be used for demand control.

 

All settings and features are accessible via touch-sensitive SAVE Touch control panel with a user friendly interface. The option for connecting one or more external control panels is available. In addition, control panel has separate user level for authorized installers and service personnel.

The home screen displays information such as airflow, temperature, air quality and active functions. You can select between MANUAL and AUTO mode or choose preferred settings from the pre-configured user modes.

AUTO mode has many functions available that regulate the airflow according to CO2, presence, humidity, schedule etc. The demand function control gives effective and economical operation to ensure best indoor air quality. Alarm symbols indicate possible malfunctions and issues direct alerts if anything needs to be rectified.

 

The unit comes with a connection board that has prewired inputs and outputs for easy installation and setup of external sensors as well as for external heaters / coolers and other accessories.

 

The unit comes with low-pressure pleated filters:

• Supply air filter ePM10 50%

• Extract air filter ePM10 50%

Low pressure pleated filter F7/ePM1 60% is available as an accessory for supply air filtering.

Bag filter sets are also available (supply + extract) as accessories:

• M5/Coarse 70% + M5/Coarse 70%

• F7/ePM1 60% + M5/Coarse70%

 

Warning: internal reheater cannot be used if unit is installed horizontally.

Note: No continuous ventilation through the cooker hood

Ecodesign

Product
Trade name Systemair
Product name SAVE VTR 100/B
Basic unit
ErP compliance 2016/2018
SEC Average -34.3 kWh/(m².a)
SEC Cold -77 kWh/(m².a)
SEC Warm -9.8 kWh/(m².a)
SEC Class A
Unit category RVU
Unit type BVU
Drive Integrated VSD
Heat recovery type Regenerative
Temperature ratio 84 %
qv max 156 m³/h
P max 83 W
Sound power level LWA 42 dB(A)
qv ref 0.03 m³/s
Ps ref 50 Pa
SPI 0.461 W/(m³/h)
CTRL 0.85
MISC 1.1
x-value 2
External Leakage 3 %
Internal Leakage Not applicable
Carry over 4 %
Type of product RAHU/AAHE
AEC average 417 kWh
AEC cold 417 kWh
AEC warm 417 kWh
AHS Average 4,467 kWh/a
AHS Cold 8,739 kWh/a
AHS Warm 2,020 kWh/a
Units with local demand control
ErP compliance 2016/2018
SEC Average -39.6 kWh/(m².a)
SEC Cold -83.3 kWh/(m².a)
SEC Warm -14.6 kWh/(m².a)
SEC Class A
Unit category RVU
Unit type BVU
Drive Integrated VSD
Heat recovery type Regenerative
Temperature ratio 84 %
qv max 156 m³/h
P max 83 W
Sound power level LWA 42 dB(A)
qv ref 0.03 m³/s
Ps ref 50 Pa
SPI 0.461 W/(m³/h)
CTRL 0.65
MISC 1.1
x-value 2
External Leakage 3 %
Internal Leakage Not applicable
Carry over 4 %
Type of product RAHU/AAHE
AEC average 244 kWh
AEC cold 244 kWh
AEC warm 244 kWh
AHS Average 4,569 kWh/a
AHS Cold 8,938 kWh/a
AHS Warm 2,066 kWh/a

Energy class label

Energy class, Basic unit

Technical parameters

Product
Voltage (nominal) 230 V
Frequency 50 Hz
Phase(s) 1~
Air flow 100 m³/h
Recommended fuse 10 A
Enclosure class IP24
Exchanger
Heat exchanger rotor drive type Variable speed
Exchanger type Rotating
Heater
Heating type None
Supply air
Input power, supply fan 35 W
Extract air
Input power, extract fan 35 W
Filter
Filter class, supply air ePM10 50%
Filter class, extract air ePM10 50%
Color casing
Color casing Galvanized steel
Dimensions and weights
Weight 39 kg
Used for
Installation placement Vertical
Supply side Right
ErP
Energy class, Basic unit A
Energy class, Local demand A
ErP ready ErP 2016; ErP 2018
1 Outdoor air

2

Supply air

3

Extract air

4

Exhaust air

Images Dimensions - Systemair
* Cooker hood connection
RFA
DXF
FK 125 Fast clamp - Systemair Item Number: 1608 FK 125 Fast clamp

SYSTEMAIR FK Fast clamps each 125 dia

.
CB 125-0,6 230V/1 Duct heater - Systemair Item Number: 5289 CB 125-0,6 230V/1 Duct heater .
CWK 125-3-2,5 Duct cooler,circ - Systemair Item Number: 30021 CWK 125-3-2,5 Duct cooler,circ

circular, d=125mm

.
LDC 125-600 Silencer - Systemair Item Number: 5190 LDC 125-600 Silencer .
LDC 125-900 Silencer - Systemair Item Number: 5191 LDC 125-900 Silencer .
Presence detector/IR24-P - Systemair Item Number: 6995 Presence detector/IR24-P .
VBC 125-2 Water heating batt - Systemair Item Number: 5457 VBC 125-2 Water heating batt .
VBC 125-3 Water heating batt - Systemair Item Number: 9839 VBC 125-3 Water heating batt .
251-10/B Cookerhood Stainless - Systemair Item Number: 96699 251-10/B Cookerhood Stainless

Centered damper hole, timer and potential free contact.

.
251-10/B Cookerhood White - Systemair Item Number: 96698 251-10/B Cookerhood White

Centered damper hole, timer and potential free contact.

.
392-10/B Slimline Int.600White - Systemair Item Number: 77265 392-10/B Slimline Int.600White

Timer and pot. free contact

.
BF VTR 100 F7/ePM1 60% Sup - Systemair Item Number: 212145 BF VTR 100 F7/ePM1 60% Sup

Bag filter F7/ePM1 60% Supply Air

.
BF VTR 100 M5/Coarse 70% S/E - Systemair Item Number: 212146 BF VTR 100 M5/Coarse 70% S/E

Bag filter M5/Coarse 70% Supply/Extract

.
BF VTR 100 OPT kit 1 - Systemair Item Number: 153717 BF VTR 100 OPT kit 1

BF kit=2pcs M5/Coarse 70%, Supply/Extract

.
BF VTR 100 OPT kit 2 - Systemair Item Number: 153718 BF VTR 100 OPT kit 2

BF kit=2pcs(F7/ePM1 60% sup and M5/Coarse 70% ext)

.
CB Preheater Kit 1 phase - Systemair Item Number: 142852 CB Preheater Kit 1 phase

Accessory to connect CB with the SAVECair controls

.
CE/CD-diverting plug 4pin - Systemair Item Number: 37367 CE/CD-diverting plug 4pin .
CEC Cable w/plug 12m - Systemair Item Number: 24782 CEC Cable w/plug 12m

Spare part - Phone cable with 4 leads and plugs for control

.
CEC Cable w/plug 6m - Systemair Item Number: 24783 CEC Cable w/plug 6m

Spare part - Phone cable with 4 leads and plugs for control

.
Ceiling mounting kit VTR 100/B - Systemair Item Number: 155980 Ceiling mounting kit VTR 100/B .
Connectduct Ø 125/1,0 M/F - Systemair Item Number: 2556 Connectduct Ø 125/1,0 M/F .
CVVX 125 Combi grille, black - Systemair Item Number: 26421 CVVX 125 Combi grille, black

RAL 9005

.
CVVX 125 Combi grille, white - Systemair Item Number: 26422 CVVX 125 Combi grille, white

RAL 9016

.
Duct Cover White VTR 100/B - Systemair Item Number: 153760 Duct Cover White VTR 100/B .
Duct sensor -30-70C - Systemair Item Number: 211524 Duct sensor -30-70C

TG-K3/NTC10-01, SAVECair

.
El. Re-heater VTR 100/B 250W - Systemair Item Number: 154100 El. Re-heater VTR 100/B 250W

250W

.
Internet access module (IAM) - Systemair Item Number: 211243 Internet access module (IAM)

SAVE Touch

.
PF VTR 100 F7/ePM1 60% Sup - Systemair Item Number: 212147 PF VTR 100 F7/ePM1 60% Sup

Pleat filter F7/ ePM1 60% Supply Air

.
PF VTR 100 M5/ePM10 50% S/E - Systemair Item Number: 212148 PF VTR 100 M5/ePM10 50% S/E

Pleat filter M5/ePM10 50% Supply/Extract

.
PF VTR 100 OPT kit - Systemair Item Number: 153716 PF VTR 100 OPT kit

PF kit=2pcs(F7/ePM1 60% sup and M5/ePM10 50% ext)

.
PF VTR 100 STD kit - Systemair Item Number: 153715 PF VTR 100 STD kit

PF kit=2pcs M5/ePM10 50%, Supply/Extract

.
Pressure guard with pitot tube - Systemair Item Number: 212987 Pressure guard with pitot tube

SR 200

.
PSS48 Transformer 24V - Systemair Item Number: 204385 PSS48 Transformer 24V .
Push button, impulse - Systemair Item Number: 9693 Push button, impulse .
RMK - Systemair Item Number: 153549 RMK

Relay mounting kit (No traf)

.
RMK-T - Systemair Item Number: 153548 RMK-T

Relay mounting kit (with traf)

.
Room sensor 0-50C - Systemair Item Number: 211525 Room sensor 0-50C

S-TG-R5/NTC10-01, SAVECair

.
RS-24V - Systemair Item Number: 159484 RS-24V

Relay AZ762-24V with socket

.
RVAZ4 24A Actuator 0-10V - Systemair Item Number: 9862 RVAZ4 24A Actuator 0-10V .
SAVE Touch Black SPR - Systemair Item Number: 138078 SAVE Touch Black SPR

Touch display black, spare part

.
SAVE Touch Wall Mounted Kit - Systemair Item Number: 140736 SAVE Touch Wall Mounted Kit

Touch display frame

.
SAVE Touch White SPR - Systemair Item Number: 138077 SAVE Touch White SPR

Touch diplay white, spare part

.
Surface sensor -30-150C - Systemair Item Number: 211523 Surface sensor -30-150C

TG-A1/NTC10-01, SAVECair

.
Systemair-1 CO2 duct sensor - Systemair Item Number: 14906 Systemair-1 CO2 duct sensor

CO2 duct sensor, 100 mm

.
Systemair-E CO2 RH Temperature - Systemair Item Number: 211522 Systemair-E CO2 RH Temperature

T8100-E-H-SA, SAVECair

.
Systemair-E CO2 sensor - Systemair Item Number: 14904 Systemair-E CO2 sensor

CO2 wall unit, no display

.
VAV/CAV conversion kit - Systemair Item Number: 140777 VAV/CAV conversion kit

SAVE Touch

.
ZTR 15-0,4 valve 3-way - Systemair Item Number: 9670 ZTR 15-0,4 valve 3-way

DN 15 Kvs 0,4

.
ZTR 15-0,6 valve 3-way - Systemair Item Number: 6573 ZTR 15-0,6 valve 3-way

DN 15 Kvs 0,6

.
ZTV 15-0,4 2-way valve - Systemair Item Number: 9829 ZTV 15-0,4 2-way valve

DN 15 Kvs 0,4

.
ZTV 15-0,6 2-way valve - Systemair Item Number: 6571 ZTV 15-0,6 2-way valve

DN 15 Kvs 0,6

.