SYSVRF2 DUCT 140 Q

VRF 2nd gen Duct 14kW 1Ph/50Hz, DC fan motor

Item Number: 316248

Features

• External static pressure up to 150 Pa.
• All models are equipped with high efficient DC fan motor.
• 7-speed fan control provides an high flexibility in supplying the correct air flow in the room.
• Washable air filter placed in an aluminum frame which is removable downward from the bottom.
• Fresh air hole, air inlet/outlet flange are standard for easy duct connection.
• Air inlet from back as standard and from bottom as optional with the same flange plate.
• Integrated drain pump with a head of 750 mm.
• Electronic expansion valve (EXV) fixed inside of the indoor unit.
• Std functional port such as remote on/off free contact.
• Display board with infrared receiver as standard equipment.
• Power supply 50Hz or 60Hz.

Accessories/options

• Infrared remote controller SYS RM 05 with address setting function.
• Wired controller SYS WSC 86 with address setting and Follow me function.
• Wired controller SYS WGC 120 with weekly timer and Group control up to 16 indoor units.

Technical parameters

Performances
Cooling capacity 14 kW
Power Input cooling 0.25 kW
Heating capacity 15.5 kW
Input power, heater 0.25 kW
General data
Frequency 50 Hz
Phase(s) 1~
Voltage (nominal) 230 V
Refrigerant type R410A
Fan type DC
Air flow 1,960 m³/h
Operating ambient temperature range cooling 17 to 32 °C
Sound data
Sound pressure level at 1m, indoor unit 41 dB(A)
Dimensions and weights
Piping diameter, gas line 15.9 mm
Piping diameter, liquid line 9.5 mm
Weight 46.5 kg
Images Wiring - SYSVRF2 DUCT 140 Q - Systemair
Images Dimensions - SYSVRF2 DUCT 140 Q - Systemair
22 Q 28 Q 36 Q 45 Q 56 Q 71 Q 90 Q 112 Q 140 Q

A

mm

700

700

700

920

920

1140

1140

1140

1200

B

mm

210

210

210

210

210

210

270

270

300

C

mm

500

500

500

500

500

500

775

775

865

D

mm

450

450

450

450

450

450

710

710

800

E

mm

780

780

780

1000

1000

1220

1230

1230

1290

F

mm

45

45

45

45

45

45

65

65

80

G

mm

512

512

512

732

732

732

933

933

969

H

mm

17

17

17

17

17

17

35

35

40

SYS RM 05 - Systemair Item Number: 316260 SYS RM 05

Infrared remote controller SYS RM 05

.
SYS WGC 120 - Systemair Item Number: 316261 SYS WGC 120

Wired group controller SYS WGC 120

.
SYS WSC 86 - Systemair Item Number: 316262 SYS WSC 86

Wired simplified controller SYS WSC 86

.
Twin CU-Tube 3/8+5/8 insul. - Systemair Item Number: 231128 Twin CU-Tube 3/8"+5/8" insul.

coil 20m, insul. 9mm wall, low flammable

.