Topvex TX/C06 HWH-R-CAV-S

Sektsioonsulatusega

Toote number: 156545

• Topvex is delivered with the Access control system

• Space saving top connection

• High efficient counter-flow heat exchanger

- > 80% dry efficiency (EN 308) at nominal airflow

- No mixing of extract and supply air

- Automatic summer operating

- Cool recovering

• Section defrosting

-

The Topvex counter flow unit TX/C (-S

*

) are pre-configured units with Section defrosting

• Low energy use

- Energy efficient plug fans with EC motors

• Large inspection doors for easy maintenance

-

All main components are easy removable

- Separate electrical cabinet facilitates commissioning and service

• Manufactured in Aluzinc plated sheet metal (AZ185)

- Corrosive class C4 (Industrial and coastal areas with moderate salinity)

- AZ185 sheet metal has more than 50 years of technical lifetime

• Factory tested

Topvex TX/C is designed for meeting the coming energy demands with high heat recovery efficiency and low energy use. To guarantee the high heat recovery efficiency the exchanger is designed for low air speed and by that also a low pressure drop. The supply and extract air filter are designed to have a low pressure drop, without compromising with the filtration efficiency. A low internal pressure drop is essential to keep the energy use down Topvex TX/C features Plug fans with EC technology to ensure high efficiency. The EC-motors has when speed-controlled, 15-20% lower energy consumption compared to a standard frequency controlled asynchrony motor.

100% By-pass of heat exchanger secures lowest possible internal pressure drop during the warm season.

A damper isolates the exchanger during the warm period ensures that there is no undesirable heat recovering.

Constant air volume control is standard and Variable air volume control is available as an accessory.

The Topvex counter flow unit TX/C with item name ending -S are pre-configured units with Section defrosting.

The Section defrosting consist of a pre-wired sectioned damper that divides the heat exchanger in three areas plus the by-pass section. All sections are controlled by individual motors for each section and are connected to a separate, pre-programmed control unit.

Section defrosting will prevent severe ice built up in the heat exchanger and allow defrosting of the heat exchanger, while still providing heat recovery through the defrosting sequence.

When activated by pressure detecting, the damper sections will be cyclic operated. Each section will operate in sequence and compensate low temperature in the exhaust air, by modulating the by-pass and section damper.

Topvex is delivered with the new Access control system. The system includes NaviPad control panel, featuring an easy-to-use intuitive HTML5 user interface.

The protection class of the NaviPad control panel is IP54 and 0-50 C° permitted temperature. The enclosure is not UV resistant and the NaviPad is not for outdoor mounting. Communication between the panel and the controller in the cabinet is possible with up to 100 meters of cable.

The NaviPad is connected via 3 meters flat cable. It is mounted on the Topvex unit or on the wall, easy to detach for handheld use.

Relevant operating data and settings are available in real time and can be changed with a few clicks.

Access control has built-in energy saving features like free cooling, cooling recovery, season related temperatures and airflow control.

Possibility to edit names for the unit, the alarms and control components gives the user options to adapt to different installations needs.

With the system overview dashboard it is possible to monitor several air handling units within a local network.

Standard communication possibilities are: Modbus RTU via RS-485 & TCP/IP & BACnet via IP.

Ordering code.

- Model: TX/C03, TX/C04 and TX/C06.

- Heating coil:

EL

(Electric).

HWL

(Hot water coil-low power).

HWH

(Hot water coil-high power).

None

(No heater).

- Right or Left model: R

(Right),

L

(Left). The side where the supply air is located when viewed from the access side.

- Airflow control: CAV

(Constant air volume).

-

Airflow control (accessory):

VAV

(Variable air volume = constant duct pressure control).

-Section defrosting:

-S

(Section defrosting).

*

Section defrosting is available for all Topvex TX/C. Units with item name ending -S are Section defrosting configured.

I.e. Topvex TX/C03 EL-L-CAV-S.

Tehnilised parameetrid

Mõõtmed ja kaal
Kaal 408 kg

Supply

Images Performance - Topvex TX/C06 HWH-R-CAV-S - Systemair

Extract

Images Performance - Topvex TX/C06 HWH-R-CAV-S - Systemair
1 Outdoor air

2

Supply air

3

Extract air

4

Exhaust air

Images Dimensions - Topvex TX/C06 HWH-R-CAV-S - Systemair
A B C D E F G H I J K L M

Topvex TX/C06

2150

1630

880

1998

725

116

196

324

140

600

197

300

1065

CO2RT-R-D transmitter - Systemair Toote number: 6993 CO2RT-R-D transmitter

displeiga

.
Presence detector/IR24-PC - Systemair Toote number: 7288 Presence detector/IR24-PC .
SAVECair CO2 andur - Systemair Toote number: 14904 SAVECair CO2 andur

pinnapealne

.
SAVECair CO2 kanaliandur - Systemair Toote number: 14906 SAVECair CO2 kanaliandur

0-10V, 100mm

.
Systemair-1M CO2 kanaliandur - Systemair Toote number: 14908 Systemair-1M CO2 kanaliandur

CO2 duct sensor, 1m cable

.
Systemair-2 CO2 duct sensor - Systemair Toote number: 14907 Systemair-2 CO2 duct sensor

CO2 duct sensor, 200 mm

.
Systemair-E-D CO2 sensor - Systemair Toote number: 14905 Systemair-E-D CO2 sensor

CO2 wall unit, with display

.
T 120 taimer - Systemair Toote number: 5165 T 120 taimer .
TG-AH1/PT1000 pinnaandur - Systemair Toote number: 7899 TG-AH1/PT1000 pinnaandur .
TG-R5/PT1000 ruumiandur 0..50° - Systemair Toote number: 5404 TG-R5/PT1000 ruumiandur 0..50° .
TG-UH/PT1000 välisandur - Systemair Toote number: 35203 TG-UH/PT1000 välisandur

temp. -30°...+70°C

.
VAV Air Volume Control - Systemair Toote number: 145946 VAV Air Volume Control .
DXRE 60-35-3-2,5 - Systemair Toote number: 7956 DXRE 60-35-3-2,5

jahutuspatarei

.
LDR 60-30 mürasummuti - Systemair Toote number: 5072 LDR 60-30 mürasummuti

kandiline

.
PGK 60-35-3-2,0 jahutuspatarei - Systemair Toote number: 6612 PGK 60-35-3-2,0 jahutuspatarei

rectangular 600x350mm

.
VBR 60-30-2 veeküttekalorifeer - Systemair Toote number: 5466 VBR 60-30-2 veeküttekalorifeer

kandiline

.
BFT TX/C06 Filter Coarse 50% - Systemair Toote number: 209932 BFT TX/C06 Filter Coarse 50%

780x560x350/9 G3

.
BFT TX/C06 Filter ePM1 60% - Systemair Toote number: 209930 BFT TX/C06 Filter ePM1 60%

780x560x350/14 F7

.
BFT TX/C06 Filter ePM10 60% - Systemair Toote number: 209931 BFT TX/C06 Filter ePM10 60%

780x560x350/9 M5

.
Corrigo S-E3-DSP displei - Systemair Toote number: 208997 Corrigo S-E3-DSP displei

kaabliga 10m

.
CTTG 400 Roof curb - Systemair Toote number: 27253 CTTG 400 Roof curb .
CTVX 400 Combi-roof hood Aluz. - Systemair Toote number: 27246 CTVX 400 Combi-roof hood Aluz. .
CTVX 400 Combi-roof hood Black - Systemair Toote number: 27242 CTVX 400 Combi-roof hood Black .
CVVX 400 Combi grille white - Systemair Toote number: 146262 CVVX 400 Combi grille white .
CVVX 400 seinaelement RAL9005 - Systemair Toote number: 6236 CVVX 400 seinaelement RAL9005 .
HMH kanali/ruumi niiskusrelee - Systemair Toote number: 13209 HMH kanali/ruumi niiskusrelee .
LDR-B 60-30 Silencer, baffle - Systemair Toote number: 9240 LDR-B 60-30 Silencer, baffle .
RVAZ4 24A Ventiiliajam 0-10V - Systemair Toote number: 9862 RVAZ4 24A Ventiiliajam 0-10V .
TG-KH/PT1000 kanaliandur - Systemair Toote number: 202705 TG-KH/PT1000 kanaliandur

temperature range: -30° - +70°C

.
Topvex RB60-30EL eelk.komplekt - Systemair Toote number: 131043 Topvex RB60-30EL eelk.komplekt .
TUNE-AHU-SE003-600x300-TF24 - Systemair Toote number: 79896 TUNE-AHU-SE003-600x300-TF24

Air damper TUNE-AHU-SE003-600x300-TF24

.
Veelukk - Systemair Toote number: 206263 Veelukk

Ø32 mm

.
ZTR 15-1,0 3-tee ventiil - Systemair Toote number: 9672 ZTR 15-1,0 3-tee ventiil

DN 15 Kvs 1,0

.
ZTV 15-0,6 2-tee ventiil - Systemair Toote number: 6571 ZTV 15-0,6 2-tee ventiil

DN 15 Kvs 0,6

.