X-VR400EV/B

Numéro article: 12461

User friendly controlling by the integrated and/or separate control panel

High efficiency rotating heat recovery unit

Changes automatically to summer operation

Flexible installation and no need for condensate drain

Automatic bypass-function when using a cooker hood.

Cool recovering

EU7 fine filter for supply-air

Demand control

VR-400 EV/B is suitable for ventilation of homes and offices. It is painted white and designed for wall installation in a utility room or similar. The unit is delivered with complete control functions, centrifugal fans for supply and extract air, rotating heat exhanger and filter.

A cooker hood can be connected to the unit via a separate connection on top of the unit. The air from the cooker hood is then led thru the unit in a separate “bypass-duct” directly to the exhaust fan and not thru the heat exchanger.

The unit automatically alternates between normal operation with heat recovery and summer operation without. This solution will also automatically recover chilled indoor air.

The CE control panel is easy to operate, with buttons for choice of air flow and supply air temperature. Lamp indicators show chosen settings, electrical heater battery in operation and if filter change is needed. Alarm menu will also show possible operation malfunctions. A separate timer can be connected for programming day and night operation. A CO2 or presence sensor (potential free contact) can be connected for demand control.

Electrical connection:

Connection to mains supply via ca. 1 m cable with earthed plug.

2 leads for potential free signal from cooker hood (if installed).

4 leads (12V) for signal from remote control panel (if installed). Connection via external plug on unit, alternatively to terminal block in the junction box. Separate twin plugs to be used for regulation from two or more remote control panels.

2 leads for signal from week timer (if installed)

Paramètres techniques

Produit
Tension nominale 230 V
Fréquence 50 Hz
Phase(s) [~] 1~
Fusible recommandé 10 A
Indice de protection IP24
Echangeur
Type d'échangeur Rotatif
Chauffage
Puissance installée; Batt. Chauf 1,67 kW
Soufflage
Puissance installée; Vent. Extraction 138 W
Air extrait
Puissance installée; Ventilateur extraction 138 W
Filtre
Classe de filtration; air soufflé EU7
Classe de filtration; air extrait EU3
Dimensions et poids
Poids 62 kg
Utilisez pour
Lieu d'installation Vertical
IGK-160 Grille - Systemair Numéro article: 1632 IGK-160 Grille

Grille extérieure + plénum à encastrer Ø160mm

.
FK 160 Manchette - Systemair Numéro article: 1610 FK 160 Manchette

Manchette de raccordement circulaire Ø160mm

.
LDC 160.600 Silencieux - Systemair Numéro article: 5192 LDC 160.600 Silencieux

Silencieux circulaire Ø160mm - longueur: 600mm

.
LDC 160.900 Silencieux - Systemair Numéro article: 5193 LDC 160.900 Silencieux

Silencieux circulaire Ø160mm - longueur: 900mm

.
BF VR400 EV F7/ePM10 80%-FDS - Systemair Numéro article: 12432 BF VR400 EV F7/ePM10 80%-FDS

Filtre Air Neuf - 174x338x475/2

.
F-T120 - Systemair Numéro article: 5137 F-T120 .