ECOM Symbol

Topvex TX/C04 HWH-R-CAV-S

Item Number: 156537

• Topvex is delivered with the Access control system

• Space saving top connection

• High efficient counter-flow heat exchanger

- > 80% dry efficiency (EN 308) at nominal airflow

- No mixing of extract and supply air

- Automatic summer operating

- Cool recovering

• Section defrosting

-

The Topvex counter flow unit TX/C (-S

*

) are pre-configured units with Section defrosting

• Low energy use

- Energy efficient plug fans with EC motors

• Large inspection doors for easy maintenance

-

All main components are easy removable

- Separate electrical cabinet facilitates commissioning and service

• Manufactured in Aluzinc plated sheet metal (AZ185)

- Corrosive class C4 (Industrial and coastal areas with moderate salinity)

- AZ185 sheet metal has more than 50 years of technical lifetime

• Factory tested

Topvex TX/C is designed for meeting the coming energy demands with high heat recovery efficiency and low energy use. To guarantee the high heat recovery efficiency the exchanger is designed for low air speed and by that also a low pressure drop. The supply and extract air filter are designed to have a low pressure drop, without compromising with the filtration efficiency. A low internal pressure drop is essential to keep the energy use down Topvex TX/C features Plug fans with EC technology to ensure high efficiency. The EC-motors has when speed-controlled, 15-20% lower energy consumption compared to a standard frequency controlled asynchrony motor.

100% By-pass of heat exchanger secures lowest possible internal pressure drop during the warm season.

A damper isolates the exchanger during the warm period ensures that there is no undesirable heat recovering.

Constant air volume control is standard and Variable air volume control is available as an accessory.

The Topvex counter flow unit TX/C with item name ending -S are pre-configured units with Section defrosting.

The Section defrosting consist of a pre-wired sectioned damper that divides the heat exchanger in three areas plus the by-pass section. All sections are controlled by individual motors for each section and are connected to a separate, pre-programmed control unit.

Section defrosting will prevent severe ice built up in the heat exchanger and allow defrosting of the heat exchanger, while still providing heat recovery through the defrosting sequence.

When activated by pressure detecting, the damper sections will be cyclic operated. Each section will operate in sequence and compensate low temperature in the exhaust air, by modulating the by-pass and section damper.

Topvex is delivered with the new Access control system. The system includes NaviPad control panel, featuring an easy-to-use intuitive HTML5 user interface.

The protection class of the NaviPad control panel is IP54 and 0-50 C° permitted temperature. The enclosure is not UV resistant and the NaviPad is not for outdoor mounting. Communication between the panel and the controller in the cabinet is possible with up to 100 meters of cable.

The NaviPad is connected via 3 meters flat cable. It is mounted on the Topvex unit or on the wall, easy to detach for handheld use.

Relevant operating data and settings are available in real time and can be changed with a few clicks.

Access control has built-in energy saving features like free cooling, cooling recovery, season related temperatures and airflow control.

Possibility to edit names for the unit, the alarms and control components gives the user options to adapt to different installations needs.

With the system overview dashboard it is possible to monitor several air handling units within a local network.

Standard communication possibilities are: Modbus RTU via RS-485 & TCP/IP & BACnet via IP.

Ordering code.

- Model: TX/C03, TX/C04 and TX/C06.

- Heating coil:

EL

(Electric).

HWL

(Hot water coil-low power).

HWH

(Hot water coil-high power).

None

(No heater).

- Right or Left model: R

(Right),

L

(Left). The side where the supply air is located when viewed from the access side.

- Airflow control: CAV

(Constant air volume).

-

Airflow control (accessory):

VAV

(Variable air volume = constant duct pressure control).

-Section defrosting:

-S

(Section defrosting).

*

Section defrosting is available for all Topvex TX/C. Units with item name ending -S are Section defrosting configured.

I.e. Topvex TX/C03 EL-L-CAV-S.

Tehnički parametri

Dimenzije i težine
Masa 299 kg

Supply

Images Performance - Topvex TX/C04 HWH-R-CAV-S - Systemair

Extract

Images Performance - Topvex TX/C04 HWH-R-CAV-S - Systemair
1 Outdoor air

2

Supply air

3

Extract air

4

Exhaust air

Images Dimensions - Topvex TX/C04 HWH-R-CAV-S - Systemair
A B C D E F G H I J K L M

Topvex TX/C04

1860

1279

880

1708

725

104

136

180

190

500

195

300

920

CO2 1M CO2 kanalski senzor - Systemair Item Number: 14908 CO2 1M CO2 kanalski senzor

CO2 duct sensor, 1m cable

.
CO2 E CO2 senzor - Systemair Item Number: 14904 CO2 E CO2 senzor

CO2 wall unit, no display

.
CO2 E-D CO2 senzor - Systemair Item Number: 14905 CO2 E-D CO2 senzor

CO2 wall unit, with display

.
CO2RT-R-D SENZOR CO2,RELE/ZAS. - Systemair Item Number: 6993 CO2RT-R-D SENZOR CO2,RELE/ZAS. .
IR 24 P IR SENZOR - Systemair Item Number: 7288 IR 24 P IR SENZOR .
Systemair-1 CO2 duct sensor - Systemair Item Number: 14906 Systemair-1 CO2 duct sensor

CO2 duct sensor, 100 mm

.
Systemair-2 CO2 duct sensor - Systemair Item Number: 14907 Systemair-2 CO2 duct sensor

CO2 duct sensor, 200 mm

.
T 120 Timer - Systemair Item Number: 5165 T 120 Timer .
TG-AH1/PT1000 POVRćIN. SENZOR - Systemair Item Number: 7899 TG-AH1/PT1000 POVRćIN. SENZOR .
TG-R5/PT1000 SOBNI SENZOR - Systemair Item Number: 5404 TG-R5/PT1000 SOBNI SENZOR .
TG-UH/PT1000 ZID.TEMP.SENZOR - Systemair Item Number: 35203 TG-UH/PT1000 ZID.TEMP.SENZOR

temperature range: -30° - +70°C

.
VAV Air Volume Control - Systemair Item Number: 145946 VAV Air Volume Control .
DS 50-30 GIBLJIVI PRIKLJUčAK - Systemair Item Number: 1544 DS 50-30 GIBLJIVI PRIKLJUčAK .
DXRE 50-30-3-2,5 Dx hladnjak - Systemair Item Number: 7953 DXRE 50-30-3-2,5 Dx hladnjak

rectangular 500x300mm

.
LDR 50-30 PRIGUćIVAč ZVUKA - Systemair Item Number: 5071 LDR 50-30 PRIGUćIVAč ZVUKA

Rectangular

.
PGK 50-30-3-2,0 KANALSKI HLAD. - Systemair Item Number: 6608 PGK 50-30-3-2,0 KANALSKI HLAD.

rectangular 500x300mm

.
VBR 50-30-2 GRIJAč VODE - Systemair Item Number: 5465 VBR 50-30-2 GRIJAč VODE .
BFT TX/C04 Filter Coarse 50% - Systemair Item Number: 209929 BFT TX/C04 Filter Coarse 50%

780x417x430/230/8 G3

.
BFT TX/C04 Filter ePM1 60% - Systemair Item Number: 209927 BFT TX/C04 Filter ePM1 60%

780x417x430/230/12 F7

.
BFT TX/C04 Filter ePM10 60% - Systemair Item Number: 209928 BFT TX/C04 Filter ePM10 60%

780x417x430/230/8 M5

.
CORRIGO E3-DSP - Systemair Item Number: 208997 CORRIGO E3-DSP

Control panel S-E3-DSP with 10m cable

.
Corrigo exp. module CEM15 - Systemair Item Number: 209554 Corrigo exp. module CEM15

Expansion module

.
CTTG 300 Roof curb - Systemair Item Number: 27252 CTTG 300 Roof curb .
CTVX 300 Combi-roof hood Aluz. - Systemair Item Number: 27245 CTVX 300 Combi-roof hood Aluz. .
CTVX 300 Combi-roof hood Black - Systemair Item Number: 27241 CTVX 300 Combi-roof hood Black .
CVVX 315 Combi grille white - Systemair Item Number: 146261 CVVX 315 Combi grille white .
CVVX 315 kombi-reć.. RAL 9005 - Systemair Item Number: 8499 CVVX 315 kombi-reć.. RAL 9005

for Topvex 1500 (Black)

.
F-T120 okvir timera - Systemair Item Number: 5137 F-T120 okvir timera .
HMH KANALSKI HIGROSTAT 1-STEP. - Systemair Item Number: 13209 HMH KANALSKI HIGROSTAT 1-STEP. .
HU Higrostat - Systemair Item Number: 30213 HU Higrostat

on wall

.
KRM-1 duct smoke detect 230V - Systemair Item Number: 35937 KRM-1 duct smoke detect 230V

stand alone, AC230V

.
LDR-B 50-30 PRIGUć. S JEDROM - Systemair Item Number: 9239 LDR-B 50-30 PRIGUć. S JEDROM .
NaviPad extension cable 10m - Systemair Item Number: 316350 NaviPad extension cable 10m

CAT5e network cable RJ45

.
Preheat.kit Topvex RB50-30 EL - Systemair Item Number: 131086 Preheat.kit Topvex RB50-30 EL .
Push button, impulse - Systemair Item Number: 9693 Push button, impulse .
RVAZ4-24A POGON VENTILA 0-10V - Systemair Item Number: 9862 RVAZ4-24A POGON VENTILA 0-10V .
Safety switch OTP16T3M 3-pole - Systemair Item Number: 213042 Safety switch OTP16T3M 3-pole

IP65

.
Safety switch OTP16T4M 4-pole - Systemair Item Number: 213044 Safety switch OTP16T4M 4-pole

IP65

.
Shunt Group Heater Compact - Systemair Item Number: 199164 Shunt Group Heater Compact

Pump 230V, Actuator 24V/0-10V, kvs 0.12-4.4

.
sifon za vodu - Systemair Item Number: 206263 sifon za vodu

Ø32 mm

.
TG-KH/PT1000 KANAL.SEN. S KUć. - Systemair Item Number: 202705 TG-KH/PT1000 KANAL.SEN. S KUć.

temperature range: -30° - +70°C

.
UG3-A4O Smoke detector - Systemair Item Number: 15043 UG3-A4O Smoke detector

Smoke detector

.
ZTR 15-1,0 3-SMJERNI VENTIL - Systemair Item Number: 9672 ZTR 15-1,0 3-SMJERNI VENTIL

DN 15 Kvs 1,0

.
ZTV 15-0,6 2-way valve - Systemair Item Number: 6571 ZTV 15-0,6 2-way valve

DN 15 Kvs 0,6

.