Simbolo ECOM

Topvex TX/C04 HWH-R-CAV-S

Item Number: 156537

• Topvex is delivered with the Access control system

• Space saving top connection

• High efficient counter-flow heat exchanger

- > 80% dry efficiency (EN 308) at nominal airflow

- No mixing of extract and supply air

- Automatic summer operating

- Cool recovering

• Section defrosting

-

The Topvex counter flow unit TX/C (-S

*

) are pre-configured units with Section defrosting

• Low energy use

- Energy efficient plug fans with EC motors

• Large inspection doors for easy maintenance

-

All main components are easy removable

- Separate electrical cabinet facilitates commissioning and service

• Manufactured in Aluzinc plated sheet metal (AZ185)

- Corrosive class C4 (Industrial and coastal areas with moderate salinity)

- AZ185 sheet metal has more than 50 years of technical lifetime

• Factory tested

Topvex TX/C is designed for meeting the coming energy demands with high heat recovery efficiency and low energy use. To guarantee the high heat recovery efficiency the exchanger is designed for low air speed and by that also a low pressure drop. The supply and extract air filter are designed to have a low pressure drop, without compromising with the filtration efficiency. A low internal pressure drop is essential to keep the energy use down Topvex TX/C features Plug fans with EC technology to ensure high efficiency. The EC-motors has when speed-controlled, 15-20% lower energy consumption compared to a standard frequency controlled asynchrony motor.

100% By-pass of heat exchanger secures lowest possible internal pressure drop during the warm season.

A damper isolates the exchanger during the warm period ensures that there is no undesirable heat recovering.

Constant air volume control is standard and Variable air volume control is available as an accessory.

The Topvex counter flow unit TX/C with item name ending -S are pre-configured units with Section defrosting.

The Section defrosting consist of a pre-wired sectioned damper that divides the heat exchanger in three areas plus the by-pass section. All sections are controlled by individual motors for each section and are connected to a separate, pre-programmed control unit.

Section defrosting will prevent severe ice built up in the heat exchanger and allow defrosting of the heat exchanger, while still providing heat recovery through the defrosting sequence.

When activated by pressure detecting, the damper sections will be cyclic operated. Each section will operate in sequence and compensate low temperature in the exhaust air, by modulating the by-pass and section damper.

Topvex is delivered with the new Access control system. The system includes NaviPad control panel, featuring an easy-to-use intuitive HTML5 user interface.

The protection class of the NaviPad control panel is IP54 and 0-50 C° permitted temperature. The enclosure is not UV resistant and the NaviPad is not for outdoor mounting. Communication between the panel and the controller in the cabinet is possible with up to 100 meters of cable.

The NaviPad is connected via 3 meters flat cable. It is mounted on the Topvex unit or on the wall, easy to detach for handheld use.

Relevant operating data and settings are available in real time and can be changed with a few clicks.

Access control has built-in energy saving features like free cooling, cooling recovery, season related temperatures and airflow control.

Possibility to edit names for the unit, the alarms and control components gives the user options to adapt to different installations needs.

With the system overview dashboard it is possible to monitor several air handling units within a local network.

Standard communication possibilities are: Modbus RTU via RS-485 & TCP/IP & BACnet via IP.

Ordering code.

- Model: TX/C03, TX/C04 and TX/C06.

- Heating coil:

EL

(Electric).

HWL

(Hot water coil-low power).

HWH

(Hot water coil-high power).

None

(No heater).

- Right or Left model: R

(Right),

L

(Left). The side where the supply air is located when viewed from the access side.

- Airflow control: CAV

(Constant air volume).

-

Airflow control (accessory):

VAV

(Variable air volume = constant duct pressure control).

-Section defrosting:

-S

(Section defrosting).

*

Section defrosting is available for all Topvex TX/C. Units with item name ending -S are Section defrosting configured.

I.e. Topvex TX/C03 EL-L-CAV-S.

Parametri tecnici

Dimensioni e pesi
Peso 299 kg

Supply

Images Performance - Topvex TX/C04 HWH-R-CAV-S - Systemair

Extract

Images Performance - Topvex TX/C04 HWH-R-CAV-S - Systemair
1 Outdoor air

2

Supply air

3

Extract air

4

Exhaust air

Images Dimensions - Topvex TX/C04 HWH-R-CAV-S - Systemair
A B C D E F G H I J K L M

Topvex TX/C04

1860

1279

880

1708

725

104

136

180

190

500

195

300

920

1 CO2 - Systemair Item Number: 14906 1 CO2

Trasduttore di CO2 da canale L=100 mm (2-2000ppm)

.
2 CO2 - Systemair Item Number: 14907 2 CO2

Trasduttore di CO2 da canale L=200 mm (2-2000ppm)

.
CO2RT-R-D - Systemair Item Number: 6993 CO2RT-R-D

Sensore CO2/temperatura da canale, uscita digitale, 24V

.
E CO2 - Systemair Item Number: 14904 E CO2

Trasduttore di CO2 da ambiente (2-2000ppm) IP50

.
E-D CO2 - Systemair Item Number: 14905 E-D CO2

Trasduttore di CO2 da ambiente (2-2000ppm) IP50

.
IR24-PC - Systemair Item Number: 7288 IR24-PC

Rilevatore di presenza per installazione a soffitto

.
Kit VAV - Systemair Item Number: 145946 Kit VAV

Kit per regolazione a portata variabile

.
T 120 - Systemair Item Number: 5165 T 120

Temporizzatore fino a 120 minuti

.
TG-AH1/PT1000 - Systemair Item Number: 7899 TG-AH1/PT1000 .
TG-R5/PT1000 - Systemair Item Number: 5404 TG-R5/PT1000

Sensore ambiente di temperatura (0…+50°C) IP30

.
TG-UH/PT1000 - Systemair Item Number: 35203 TG-UH/PT1000

Sensore esterno di temperatura (-30…+70°C) IP65

.
DS 50-30 - Systemair Item Number: 1544 DS 50-30

Connessione flessibile flangiata

.
DXRE 50-30-3-2,5 - Systemair Item Number: 7953 DXRE 50-30-3-2,5

Batteria ad espansione diretta per canale rettangolare

.
LDR 50-30 - Systemair Item Number: 5071 LDR 50-30

Silenziatore rettangolare flangiato (50 mm lana di vetro)

.
PGK 50-30-3-2,0 - Systemair Item Number: 6608 PGK 50-30-3-2,0

Batteria ad acqua calda/fredda da canale, flangiata

.
VBR 50-30-2 - Systemair Item Number: 5465 VBR 50-30-2

Batteria ad acqua rettangolare flangiata

.
Control panel S-E3-DSP - Systemair Item Number: 208997 Control panel S-E3-DSP

Control panel S-E3-DSP with 10m cable

.
CVVX 315 black - Systemair Item Number: 8499 CVVX 315 black

Griglia combi con flussi di mandata e aspirazione separati

.
F-T120 - Systemair Item Number: 5137 F-T120

Cornice timer per montaggio a parete

.
Filtro F7 mandata - Systemair Item Number: 209927 Filtro F7 mandata

Filtro F7 a tasche per TOPVEX TX/C04

.
Filtro M5 ripresa - Systemair Item Number: 209928 Filtro M5 ripresa

Filtro M5 a tasche per TOPVEX TX/C04

.
HMH UMIDOSTATO - Systemair Item Number: 13209 HMH UMIDOSTATO

Umidostato

.
HU Hygrostat - Systemair Item Number: 30213 HU Hygrostat

on wall

.
KRM-1 duct smoke detect 230V - Systemair Item Number: 35937 KRM-1 duct smoke detect 230V

stand alone, AC230V

.
LDR-B 50-30 - Systemair Item Number: 9239 LDR-B 50-30

Silenziatore a setti fonoassorbenti a sezione quadrata

.
PB - Systemair Item Number: 9693 PB .
RVAZ4 24A 0-10V - Systemair Item Number: 9862 RVAZ4 24A 0-10V

Servomotore per valvola a sfera ZTR/ZTV

.
Safety switch 7,5kW - Systemair Item Number: 214940 Safety switch 7,5kW

3 pole + NO

.
Shunt Group Heater Compact - Systemair Item Number: 199164 Shunt Group Heater Compact

Pump 230V, Actuator 24V/0-10V, kvs 0.12-4.4

.
TG-KH/PT1000 - Systemair Item Number: 202705 TG-KH/PT1000

Sensore di temperatura da canale (-30…+70°C) IP65

.
TUNE-AHU-SE002-500x300-TF24 - Systemair Item Number: 79895 TUNE-AHU-SE002-500x300-TF24

Serranda di regolazione rettangolare con attuatore 24 volt

.
UG3-A4O - Systemair Item Number: 15043 UG3-A4O

Rilevatore di fumo da canale

.
VOC - Systemair Item Number: 156812 VOC

Sensore ambiente 24V AC/DC 0-10V, 4-20mA

.
VOC Duct sensor - Systemair Item Number: 156813 VOC Duct sensor

24V AC/DC 0-10V, 4-20mA w/ sw. contact

.
Water-lock - Systemair Item Number: 206263 Water-lock

Ø32 mm

.
ZTR 15-1,0 - Systemair Item Number: 9672 ZTR 15-1,0

Valvola acqua a sfera a 3 vie

.
ZTV 15-0,6 - Systemair Item Number: 6571 ZTV 15-0,6

Valvola a 2 vie per batteria

.