Šis produktas yra nutrauktas

AXC 450 (F)

smoke extract axial fan 400°/2h

Prekės Numeris: C450AXCF

Smoke extract axial fan AXC(F):

⁻ Certified according to EN 12101-3 for 400°C/120 min.

⁻ CE mark of conformity.

⁻ Suitable for use inside or outside the fire zone. Temperature of medium for continuous operation from -20°C up to 55°C. Air direction from motor to impeller.

Impeller:

⁻ The adjustable blade angle allows flexible and exact adjustment to the desired working point with optimum efficiency. The blade angle is pre-set in the factory.

⁻ Impellers with profiled blades made of cast aluminum alloy.

⁻ Dynamically balanced according to ISO 21940-11 and ISO 14694, balancing quality G6,3.

Casing:

⁻ Manufactured from hot-dip galvanized sheet steel according to ISO 1461.

⁻ Pre-drilled, rolled Eurovent 1/2 flanges pressed on both sides provide additional stability.

⁻ Pre-wired terminal box on fan casing for easy electrical connection, IP65 (IEC 60034-5).

⁻ PV version: Includes bolt-on outlet guide vanes which increases fan pressure and efficiency.

Motor:

⁻ Motor suitable for 400°C/120min or 55°C continuous operation.

⁻ High efficiency three-phase asynchronous motors with squirrel cage rotor, directly in the air stream.

⁻ Protection class IP55 (IEC 60034-5), insulation class H.

⁻ The motors can be equipped with PTC thermistors for motor protection (on request).

⁻ Single and two-speed motors are available.

⁻ Speed controllable via frequency converter, suitable for turn down to 10Hz.

The AXC(F) axial fans have been tested in Systemair’s AMCA certified Laboratory according to ISO 5801 and AMCA 210.

Techniniai parametrai

Nominalūs duomenys
Maks. pratekančio oro temperatūra 120 min. 400 °C
Maks. pratekančio oro temperatūra maks 55 °C
Išmatavimai ir svoriai
Svoris 0 kg
Images Dimensions - AXC 450 (F) - Systemair
* Air direction: S

ØDa

ØDi

hF

ØTk

M

s

zxØd

L

K

530

450

315

500

400

2,5

8x12

500

435

** Air direction: SO/SU (SO = air direction upwards; SU = air direction downwards)

ØDa

ØDi

K

zxØd

M

nxØdF

s

L

530

450

630

8x12

710

4x11

2,5

650

Smoke extract axial fan AXC(F) certified according to EN 12101-3 for 400°C/120 min.

CE mark of conformity.

Suitable for use inside or outside the fire zone. Temperature of medium for continuous operation from -20°C up to 55°C.

Impeller:

Impellers with profiled blades made of cast aluminum alloy

Dynamically balanced according to ISO 21940-11 and ISO 14694, balancing quality G6,3.

Casing:

Manufactured from hot-dip galvanized sheet steel according to ISO 1461.

Pre-drilled, rolled Eurovent 1/2 flanges pressed on both sides.

Pre-wired terminal box on fan casing, IP65 (IEC 60034-5).

PV Version includes bolt-on outlet guide vanes.

Motor:

Motor suitable for 400°C/120min or 55°C continuous operation.

High efficiency three-phase asynchronous motors with squirrel cage rotor, directly in the air stream.

Protection class IP55 (IEC 60034-5), insulation class H.

The motors can be equipped with PTC thermistors for motor protection (on request).

Speed controllable via frequency converter.

ESD-F 450 Perėjimas AXC - Systemair Prekės Numeris: 305259 ESD-F 450 Perėjimas AXC

with flange

.
GFL-AR/AXC 450 flanšas - Systemair Prekės Numeris: 8379 GFL-AR/AXC 450 flanšas .
LRK 450(F)air oper.Sklendė - Systemair Prekės Numeris: 8319 LRK 450(F)air oper.Sklendė .
MFA AXC/AM 450 montaž. kojelė - Systemair Prekės Numeris: 311286 MFA AXC/AM 450 montaž. kojelė

hf=315mm, 1 pc.

.
SG AXC/AM 450 aps.grotelė - Systemair Prekės Numeris: 310688 SG AXC/AM 450 aps.grotelė .
ABS 450 AXC gaubtas - Systemair Prekės Numeris: 302953 ABS 450 AXC gaubtas .