ECOM Symbol

Topvex TX/C04 HWH-R-CAV-S

Item Number: 156537

• Topvex is delivered with the Access control system

• Space saving top connection

• High efficient counter-flow heat exchanger

- > 80% dry efficiency (EN 308) at nominal airflow

- No mixing of extract and supply air

- Automatic summer operating

- Cool recovering

• Section defrosting

-

The Topvex counter flow unit TX/C (-S

*

) are pre-configured units with Section defrosting

• Low energy use

- Energy efficient plug fans with EC motors

• Large inspection doors for easy maintenance

-

All main components are easy removable

- Separate electrical cabinet facilitates commissioning and service

• Manufactured in Aluzinc plated sheet metal (AZ185)

- Corrosive class C4 (Industrial and coastal areas with moderate salinity)

- AZ185 sheet metal has more than 50 years of technical lifetime

• Factory tested

Topvex TX/C is designed for meeting the coming energy demands with high heat recovery efficiency and low energy use. To guarantee the high heat recovery efficiency the exchanger is designed for low air speed and by that also a low pressure drop. The supply and extract air filter are designed to have a low pressure drop, without compromising with the filtration efficiency. A low internal pressure drop is essential to keep the energy use down Topvex TX/C features Plug fans with EC technology to ensure high efficiency. The EC-motors has when speed-controlled, 15-20% lower energy consumption compared to a standard frequency controlled asynchrony motor.

100% By-pass of heat exchanger secures lowest possible internal pressure drop during the warm season.

A damper isolates the exchanger during the warm period ensures that there is no undesirable heat recovering.

Constant air volume control is standard and Variable air volume control is available as an accessory.

The Topvex counter flow unit TX/C with item name ending -S are pre-configured units with Section defrosting.

The Section defrosting consist of a pre-wired sectioned damper that divides the heat exchanger in three areas plus the by-pass section. All sections are controlled by individual motors for each section and are connected to a separate, pre-programmed control unit.

Section defrosting will prevent severe ice built up in the heat exchanger and allow defrosting of the heat exchanger, while still providing heat recovery through the defrosting sequence.

When activated by pressure detecting, the damper sections will be cyclic operated. Each section will operate in sequence and compensate low temperature in the exhaust air, by modulating the by-pass and section damper.

Topvex is delivered with the new Access control system. The system includes NaviPad control panel, featuring an easy-to-use intuitive HTML5 user interface.

The protection class of the NaviPad control panel is IP54 and 0-50 C° permitted temperature. The enclosure is not UV resistant and the NaviPad is not for outdoor mounting. Communication between the panel and the controller in the cabinet is possible with up to 100 meters of cable.

The NaviPad is connected via 3 meters flat cable. It is mounted on the Topvex unit or on the wall, easy to detach for handheld use.

Relevant operating data and settings are available in real time and can be changed with a few clicks.

Access control has built-in energy saving features like free cooling, cooling recovery, season related temperatures and airflow control.

Possibility to edit names for the unit, the alarms and control components gives the user options to adapt to different installations needs.

With the system overview dashboard it is possible to monitor several air handling units within a local network.

Standard communication possibilities are: Modbus RTU via RS-485 & TCP/IP & BACnet via IP.

Ordering code.

- Model: TX/C03, TX/C04 and TX/C06.

- Heating coil:

EL

(Electric).

HWL

(Hot water coil-low power).

HWH

(Hot water coil-high power).

None

(No heater).

- Right or Left model: R

(Right),

L

(Left). The side where the supply air is located when viewed from the access side.

- Airflow control: CAV

(Constant air volume).

-

Airflow control (accessory):

VAV

(Variable air volume = constant duct pressure control).

-Section defrosting:

-S

(Section defrosting).

*

Section defrosting is available for all Topvex TX/C. Units with item name ending -S are Section defrosting configured.

I.e. Topvex TX/C03 EL-L-CAV-S.

Tehnični parametri

Dimenzije in teža
Teža 299 kg

Supply

Images Performance - Topvex TX/C04 HWH-R-CAV-S - Systemair

Extract

Images Performance - Topvex TX/C04 HWH-R-CAV-S - Systemair
1 Outdoor air

2

Supply air

3

Extract air

4

Exhaust air

Images Dimensions - Topvex TX/C04 HWH-R-CAV-S - Systemair
A B C D E F G H I J K L M

Topvex TX/C04

1860

1279

880

1708

725

104

136

180

190

500

195

300

920

CO2RT-R-D TIPALO CO2,RELE/ZAS. - Systemair Item Number: 6993 CO2RT-R-D TIPALO CO2,RELE/ZAS. .
IR 24 P IR SENZOR - Systemair Item Number: 7288 IR 24 P IR SENZOR .
Senzor CO2 kanal. Systemair-2 - Systemair Item Number: 14907 Senzor CO2 kanal. Systemair-2

Systemair-2 CO2 kanalski.senzor

.
Senzor CO2/temp. sobni - Systemair Item Number: 14904 Senzor CO2/temp. sobni

Systemair-E CO2 sensor

.
Systemair-1 CO2 kanal. senzor - Systemair Item Number: 14906 Systemair-1 CO2 kanal. senzor

CO2 duct sensor, 100 mm

.
Systemair-1M CO2 kanal. sensor - Systemair Item Number: 14908 Systemair-1M CO2 kanal. sensor

CO2 duct sensor, 1m cable

.
Systemair-E-D CO2 sensor - Systemair Item Number: 14905 Systemair-E-D CO2 sensor

CO2 wall unit, with display

.
T 120 Timer - Systemair Item Number: 5165 T 120 Timer .
TG-AH1/PT1000 NALEZNO TIPALO - Systemair Item Number: 7899 TG-AH1/PT1000 NALEZNO TIPALO .
TG-R5/PT1000 sobni senzor temp - Systemair Item Number: 5404 TG-R5/PT1000 sobni senzor temp

TG-R5/PT1000 PROSTORSKO TEMPERATURNO TIPALO PT1000

.
TG-UH/PT1000 ZUN. TEMP.TIPALO - Systemair Item Number: 35203 TG-UH/PT1000 ZUN. TEMP.TIPALO

temperature range: -30° - +70°C

.
VAV Air Volume Control - Systemair Item Number: 145946 VAV Air Volume Control .
DS 50-30 gibljiv priključek - Systemair Item Number: 1544 DS 50-30 gibljiv priključek .
DXRE 50-30-3-2,5 Dx hladilnik - Systemair Item Number: 7953 DXRE 50-30-3-2,5 Dx hladilnik

rectangular 500x300mm

.
LDR 50-30 DUSILNIK ZVOKA - Systemair Item Number: 5071 LDR 50-30 DUSILNIK ZVOKA

Rectangular

.
PGK 50-30-3-2,0 KANALSKI HLAD. - Systemair Item Number: 6608 PGK 50-30-3-2,0 KANALSKI HLAD.

rectangular 500x300mm

.
VBR 50-30-2 VODNI GRELNIK - Systemair Item Number: 5465 VBR 50-30-2 VODNI GRELNIK .
CTTG 300 Roof curb - Systemair Item Number: 27252 CTTG 300 Roof curb .
CTVX 300 Combi-roof hood Aluz. - Systemair Item Number: 27245 CTVX 300 Combi-roof hood Aluz. .
CTVX 300 Combi-roof hood Black - Systemair Item Number: 27241 CTVX 300 Combi-roof hood Black .
CVVX 315 Combi grille white - Systemair Item Number: 146261 CVVX 315 Combi grille white .
CVVX 315 kombi-reš.. RAL 9005 - Systemair Item Number: 8499 CVVX 315 kombi-reš.. RAL 9005

for Topvex 1500 (Black)

.
F-T120 okvir timerja - Systemair Item Number: 5137 F-T120 okvir timerja .
FILTER TOPVEX TX/C04 F7 DOVOD - Systemair Item Number: 209927 FILTER TOPVEX TX/C04 F7 DOVOD

780x417x430/230/12 F7

.
FILTER TOPVEX TX/C04 M5 ODVOD - Systemair Item Number: 209928 FILTER TOPVEX TX/C04 M5 ODVOD

780x417x430/230/8 M5

.
HMH KANALSKI HIGROSTAT 1-STOP. - Systemair Item Number: 13209 HMH KANALSKI HIGROSTAT 1-STOP. .
KRM-1 duct smoke detect 230V - Systemair Item Number: 35937 KRM-1 duct smoke detect 230V

stand alone, AC230V

.
LDR-B 50-30 DUšILNIK Z JEDROM - Systemair Item Number: 9239 LDR-B 50-30 DUšILNIK Z JEDROM .
NaviPad extension cable 10m - Systemair Item Number: 316350 NaviPad extension cable 10m

CAT5e network cable RJ45

.
Preheat. kit Topvex RB50-30 EL - Systemair Item Number: 131086 Preheat. kit Topvex RB50-30 EL .
Prikazovalnik E3-DSP Corrigo - Systemair Item Number: 208997 Prikazovalnik E3-DSP Corrigo

Servisni prikazovalnik, krmilno krmilni

.
RVAZ4-24A 0-10V Pogon ventila - Systemair Item Number: 9862 RVAZ4-24A 0-10V Pogon ventila .
Safety switch OTP16T3M 3-pole - Systemair Item Number: 213042 Safety switch OTP16T3M 3-pole

IP65

.
Safety switch OTP16T4M 4-pole - Systemair Item Number: 213044 Safety switch OTP16T4M 4-pole

IP65

.
Sifon podtlacni SYS - Systemair Item Number: 206263 Sifon podtlacni SYS

Ø32 mm

.
TG-KH/PT1000 kanal. senz. temp - Systemair Item Number: 202705 TG-KH/PT1000 kanal. senz. temp

Senzor temp. kanalski KH/PT1000 z ohisjem

.
TUNE-AHU-SE002-500x300-TF24 - Systemair Item Number: 79895 TUNE-AHU-SE002-500x300-TF24

Air damper TUNE-AHU-SE002-500x300-TF24

.
ZTV 15-0,6 2-smerni ventil - Systemair Item Number: 6571 ZTV 15-0,6 2-smerni ventil

DN 15 Kvs 0,6

.