Topvex TX/C04 HWH-R-CAV-S

Item Number: 156537

• Topvex is delivered with the Access control system

• Space saving top connection

• High efficient counter-flow heat exchanger

- > 80% dry efficiency (EN 308) at nominal airflow

- No mixing of extract and supply air

- Automatic summer operating

- Cool recovering

• Section defrosting

-

The Topvex counter flow unit TX/C (-S

*

) are pre-configured units with Section defrosting

• Low energy use

- Energy efficient plug fans with EC motors

• Large inspection doors for easy maintenance

-

All main components are easy removable

- Separate electrical cabinet facilitates commissioning and service

• Manufactured in Aluzinc plated sheet metal (AZ185)

- Corrosive class C4 (Industrial and coastal areas with moderate salinity)

- AZ185 sheet metal has more than 50 years of technical lifetime

• Factory tested

Topvex TX/C is designed for meeting the coming energy demands with high heat recovery efficiency and low energy use. To guarantee the high heat recovery efficiency the exchanger is designed for low air speed and by that also a low pressure drop. The supply and extract air filter are designed to have a low pressure drop, without compromising with the filtration efficiency. A low internal pressure drop is essential to keep the energy use down Topvex TX/C features Plug fans with EC technology to ensure high efficiency. The EC-motors has when speed-controlled, 15-20% lower energy consumption compared to a standard frequency controlled asynchrony motor.

100% By-pass of heat exchanger secures lowest possible internal pressure drop during the warm season.

A damper isolates the exchanger during the warm period ensures that there is no undesirable heat recovering.

Constant air volume control is standard and Variable air volume control is available as an accessory.

The Topvex counter flow unit TX/C with item name ending -S are pre-configured units with Section defrosting.

The Section defrosting consist of a pre-wired sectioned damper that divides the heat exchanger in three areas plus the by-pass section. All sections are controlled by individual motors for each section and are connected to a separate, pre-programmed control unit.

Section defrosting will prevent severe ice built up in the heat exchanger and allow defrosting of the heat exchanger, while still providing heat recovery through the defrosting sequence.

When activated by pressure detecting, the damper sections will be cyclic operated. Each section will operate in sequence and compensate low temperature in the exhaust air, by modulating the by-pass and section damper.

Topvex is delivered with the new Access control system. The system includes NaviPad control panel, featuring an easy-to-use intuitive HTML5 user interface.

The protection class of the NaviPad control panel is IP54 and 0-50 C° permitted temperature. The enclosure is not UV resistant and the NaviPad is not for outdoor mounting. Communication between the panel and the controller in the cabinet is possible with up to 100 meters of cable.

The NaviPad is connected via 3 meters flat cable. It is mounted on the Topvex unit or on the wall, easy to detach for handheld use.

Relevant operating data and settings are available in real time and can be changed with a few clicks.

Access control has built-in energy saving features like free cooling, cooling recovery, season related temperatures and airflow control.

Possibility to edit names for the unit, the alarms and control components gives the user options to adapt to different installations needs.

With the system overview dashboard it is possible to monitor several air handling units within a local network.

Standard communication possibilities are: Modbus RTU via RS-485 & TCP/IP & BACnet via IP.

Ordering code.

- Model: TX/C03, TX/C04 and TX/C06.

- Heating coil:

EL

(Electric).

HWL

(Hot water coil-low power).

HWH

(Hot water coil-high power).

None

(No heater).

- Right or Left model: R

(Right),

L

(Left). The side where the supply air is located when viewed from the access side.

- Airflow control: CAV

(Constant air volume).

-

Airflow control (accessory):

VAV

(Variable air volume = constant duct pressure control).

-Section defrosting:

-S

(Section defrosting).

*

Section defrosting is available for all Topvex TX/C. Units with item name ending -S are Section defrosting configured.

I.e. Topvex TX/C03 EL-L-CAV-S.

Technical parameters

Dimensions and weights
Weight 299 kg

Supply

Images Performance - Topvex TX/C04 HWH-R-CAV-S - Systemair

Extract

Images Performance - Topvex TX/C04 HWH-R-CAV-S - Systemair
1 Outdoor air

2

Supply air

3

Extract air

4

Exhaust air

Images Dimensions - Topvex TX/C04 HWH-R-CAV-S - Systemair
A B C D E F G H I J K L M

Topvex TX/C04

1860

1279

880

1708

725

104

136

180

190

500

195

300

920

CO2RT-R-D odašiljač - Systemair Item Number: 6993 CO2RT-R-D odašiljač .
Presence detector/IR24-PC - Systemair Item Number: 7288 Presence detector/IR24-PC .
Systemair-1 CO2kanalski senzor - Systemair Item Number: 14906 Systemair-1 CO2kanalski senzor

CO2 duct sensor, 100 mm

.
Systemair-1M CO2 duct sensor - Systemair Item Number: 14908 Systemair-1M CO2 duct sensor

CO2 duct sensor, 1m cable

.
Systemair-2 CO2kanalski senzor - Systemair Item Number: 14907 Systemair-2 CO2kanalski senzor

CO2 duct sensor, 200 mm

.
Systemair-E CO2 sensor - Systemair Item Number: 14904 Systemair-E CO2 sensor

CO2 wall unit, no display

.
Systemair-E-D CO2 sensor - Systemair Item Number: 14905 Systemair-E-D CO2 sensor

CO2 wall unit, with display

.
T 120 tajmer - Systemair Item Number: 5165 T 120 tajmer .
TG-AH1/PT1000 kontaktni senzor - Systemair Item Number: 7899 TG-AH1/PT1000 kontaktni senzor .
TG-R5/PT1000sobni senzor 0-50° - Systemair Item Number: 5404 TG-R5/PT1000sobni senzor 0-50° .
TG-UH/PT1000 zidni senzor - Systemair Item Number: 35203 TG-UH/PT1000 zidni senzor

temperature range: -30° - +70°C

.
VAV Air Volume Control - Systemair Item Number: 145946 VAV Air Volume Control .
DS 50-30 - Systemair Item Number: 1544 DS 50-30

Fleksibilna veza za pravougaone kanale

.
DXRE 50-30-3-2,5 - Systemair Item Number: 7953 DXRE 50-30-3-2,5

Kanalski hladnjak

.
LDR 50-30 prigušivač - Systemair Item Number: 5071 LDR 50-30 prigušivač

Rectangular

.
PGK 50-30-3-2,0 - Systemair Item Number: 6608 PGK 50-30-3-2,0

Kanalski hladnjak

.
VBR 50-30-2 izmenjivač toplote - Systemair Item Number: 5465 VBR 50-30-2 izmenjivač toplote

Vodeni grejač

.
BFT TX/C04 Filter Coarse 50% - Systemair Item Number: 209929 BFT TX/C04 Filter Coarse 50%

780x417x430/230/8 G3

.
BFT TX/C04 Filter ePM1 60% - Systemair Item Number: 209927 BFT TX/C04 Filter ePM1 60%

780x417x430/230/12 F7

.
BFT TX/C04 Filter ePM10 60% - Systemair Item Number: 209928 BFT TX/C04 Filter ePM10 60%

780x417x430/230/8 M5

.
Control panel S-E3-DSP - Systemair Item Number: 208997 Control panel S-E3-DSP

Control panel S-E3-DSP with 10m cable

.
Corrigo exp. module CEM15 - Systemair Item Number: 209554 Corrigo exp. module CEM15

Expansion module

.
CVVX 315 Combi grille white - Systemair Item Number: 146261 CVVX 315 Combi grille white .
CVVX 315 Combi grille, black - Systemair Item Number: 8499 CVVX 315 Combi grille, black

for Topvex 1500 (Black)

.
F-T120 Timer frame - Systemair Item Number: 5137 F-T120 Timer frame .
HMH cevni higrostat IP 54 - Systemair Item Number: 13209 HMH cevni higrostat IP 54 .
LDR-B 50-30 prigušivač - Systemair Item Number: 9239 LDR-B 50-30 prigušivač .
Preheat.kit Topvex RB50-30 EL - Systemair Item Number: 131086 Preheat.kit Topvex RB50-30 EL .
Push button, impulse - Systemair Item Number: 9693 Push button, impulse .
RVAZ4 24A aktuatr 0-10V - Systemair Item Number: 9862 RVAZ4 24A aktuatr 0-10V .
Safety switch OTP16T3M 3-pole - Systemair Item Number: 213042 Safety switch OTP16T3M 3-pole

IP65

.
Safety switch OTP16T4M 4-pole - Systemair Item Number: 213044 Safety switch OTP16T4M 4-pole

IP65

.
TG-KH/PT1000 kanalski senzor - Systemair Item Number: 202705 TG-KH/PT1000 kanalski senzor

temperature range: -30° - +70°C

.
UG-3-A4O detektor dima - Systemair Item Number: 15043 UG-3-A4O detektor dima

Smoke detector

.
VOC Duct sensor - Systemair Item Number: 156813 VOC Duct sensor

24V AC/DC 0-10V, 4-20mA w/ sw. contact

.
VOC Room sensor - Systemair Item Number: 156812 VOC Room sensor

24V AC/DC 0-10V, 4-20mA w/ sw. contact

.
Water-lock - Systemair Item Number: 206263 Water-lock

Ø32 mm

.
ZTR 15-1,0 valve 3-way - Systemair Item Number: 9672 ZTR 15-1,0 valve 3-way

DN 15 Kvs 1,0

.
ZTV 15-0,6 2-way valve - Systemair Item Number: 6571 ZTV 15-0,6 2-way valve

DN 15 Kvs 0,6

.